Description
OVERVIEW
The S2600 series switch is a layer 3 Ethernet switch, which can meet the needs of cost-effective Gigabit access and 10 Gigabit uplink for enterprise networks and operator customers.S2600 uses a high-performance low-power network processor, provides Gigabit line-speed forwarding performance, supports green Ethernet line sleep capability, has the lowest power consumption of the same-level equipment in the industry, supports powerful QoS and ACL functions, and supports IP+MAC+ Security features such as port binding support service flow classification and packet priority marking. Support static data packet sampling, SFLOW function, support multi-port mirroring analysis function, support static and flexible QinQ function, support Ethernet OAM 802.3ag (CFM), 802.3ah (EFM), support strategy-based IPV4/6 unicast routing, support Flexible forwarding strategy.
Product Feature:
Carrier-level equipment stability
Based on Linux operating system, support IPv4/IPv6 dual protocol stack platform
Support multiple link redundancy and network redundancy protocols such as STP/RSTP/MSTP/ERPS/LACP
Perfect safety mechanism
Support ACL security filtering mechanism, which can provide security control functions based on MAC, IP, L4 port
Support ARP attack automatic protection and user blocking functions
Support DHCP attack automatic protection based on Mac Address and user blocking functions
Support DDOS and virus attack protection
Support DHCP-snooping/IP-source-Guard/802.1X and other security features
Support link protection functions such as BFD, FlexLink, LACP and ERRP
Support remote loop detection function
Support CFM、EFM
Support remote user authentication based on Tacacs+, Radius, and Local user authentication
Powerful QoS capabilities
Support port speed and flow speed limit function
Support classification based on service flow and Qos flow control function
Support queue scheduling algorithms such as SP/WRR/SP+WRR
Support port-based and service flow-based mirroring functions
Enhanced multi-service capabilities
Support DHCP Server and DHCP Relay
Support L2-Tunnel
Support Ethernet OAM protocol such as CFM、EFM
Rich routing protocol
Support static route
Support dynamic route such as RIP, OSPF,BGP, ISIS
Support IPV4/IPV6 dual protocol stack,Support RIPng、OSPFv3
Simple and easy-to-use network management function
Support CLI based on RS232 serial port, Telnet and SSHv2
Support WEB-based configure operation management, support SNMP V1/V2/V3
Support remote upgrade or equipment through FTP and TFTP
Datasheet
CHARACTERISTICS
1. Basic |
Product Name |
S2648-6X |
S2624-4X |
Product Positioning |
Enterprise / Metro / HCI (Hyper-Converged Infrastructure) network access or aggregation |
Switching Method |
Store and Forwarding / Cut Through |
Packet Buffer |
16Mbit |
12Mbit |
CPU Model/ Frequency |
SOC(MIPS-Dual Core Up to 1GHz) |
SOC(MIPS-34Kc Up to 800MHz) |
Flash |
32MB(FLASH) |
Memory |
512MB(DDR3) |
Hardware Configuration |
Main Board Spec |
48*10/100/1000M Base-T
6*1000M Base-X SFP/10GE SFP+ |
24*10/100/1000M Base-T
4*1000M Base-X SFP/10GE SFP+ |
Console Type |
RJ45 |
Outband Eth Management Port |
Support |
Inband Eth Management Port |
Support |
2. Performance Spec |
Switching Capacity |
Switching Capability |
216 Gbps |
128 Gbps |
Throughput |
160.704 Mpps |
95.232 Mpps |
Latency |
Min: 660ns |
3. Hardware and Software Description |
Hardware Summary |
Standard 1U 19” Rack Mountable
48*10/100/1000M Base-T
6*1000M Base-X SFP/10GE SFP+ |
Standard 1U 19” Rack Mountable
24*10/100/1000M Base-T
4*1000M Base-X SFP/10GE SFP+ |
Software Upgrade Method |
TFTP/FTP |
Service interruption time when reboot system for software update |
Less Than 120s |
4. The Power Supply and Power Requirements |
Type of Power Supply |
AC |
Support |
DC |
Support |
Power Supply Range |
AC |
Operating Voltage: 100 ~ 240V; 50/60Hz
Maximum Voltage: 90 ~ 264V; 47~63Hz |
DC |
Operating Voltage: -48V ~ -75V |
Double Power Input |
Support(Fixed) |
NO Support |
Max Power Draw |
53W |
22W |
5. Overcurrent and overvoltage protection |
Overcurrent/Overvoltage Protection |
Yes |
Surge Protection Level |
2 KV |
6. Others |
Hardware Size (H×W×D) in. |
440 x 290 x 44mm |
440 x 210 x 44mm |
Weight (kg) |
5kg |
3kg |
Cooling Mode |
Fan Cooling (Front-to-Rear Airflow) |
Quantity of Fans |
2 |
1 |
Fan Module Pluggable |
Not support (Fixed fan)
Not Support (Fixed Fan) |
Fan Module Intelligent Speed Control |
NO Support
Support |
Operating Temperature Range |
-10℃~55℃ |
SOFTWARE FEATURE LIST
Tips :● Support ○ Unsupport
Feature List |
Feature |
Description |
S2624-4X |
S2648-6X |
Type |
Sub Type |
Feature |
Ethernet basic features |
Ethernet |
Interface |
Ethernet interface operating modes(full duplex, half duplex, and auto-negotiation) |
● |
● |
Ethernet interface operating rates |
● |
● |
Jumbo Frame |
● |
● |
Port enable/disable |
● |
● |
Flow-control |
Flow-control tx/rx |
● |
● |
Storm-control |
Port based storm-control |
● |
● |
Unknow-unicast/unknow-multicast/broadcast storm-control |
● |
● |
Port-isolate |
Port-isolate |
● |
● |
Forward mode |
Store-and-forward |
● |
● |
Cut-through |
● |
● |
VLAN |
VLAN Access mode |
Access/Trunk/Hybrid |
● |
● |
Default VLAN |
● |
● |
VLAN Classification |
VLAN Classification(port based/mac based/ip based/protocal based) |
● |
● |
QinQ |
Basic QinQ |
● |
● |
Flexible QinQ |
● |
● |
VLAN Swap |
● |
● |
MAC |
MAC Address Table |
Automatic learning and aging of MAC addresses |
● |
● |
Hardware Learning |
● |
● |
Static and dynamic MAC address entries |
● |
● |
blackhole MAC |
● |
● |
LAG |
Link aggregation |
Static-LAG & LACP |
● |
● |
LAG load balance(SIP/DIP/SMAC/DMAC) |
● |
● |
Ethernet Ring protection features |
STP |
STP |
Spanning-Tree Protocol |
● |
● |
RSTP |
Rapid Spanning-Tree Protocol |
● |
● |
MSTP |
Multi-instance Spanning-Tree Protocol |
● |
● |
Spanning-Tree Protocol Protection |
BPDU Filter/Guard |
● |
● |
Root Guard |
● |
● |
Loop Guard |
● |
● |
ERPS |
ERPS |
Single Ring |
● |
● |
Sub Ring |
● |
● |
Loopback Detect |
Loopback Detect |
Loopback-detection |
● |
● |
Layer2 Multicast |
Layer2 Multicast |
IGMP Snooping |
IGMPv1/v2/v3 Snooping |
● |
● |
Fast leave |
● |
● |
Static IGMP snooping group |
● |
● |
MVR |
MVR(Multicast VLAN Registration) |
● |
● |
IPv4 Forwarding |
ARP |
ARP |
Static and dynamic ARP entries |
● |
● |
Aging of ARP entries |
● |
● |
Gratuitous ARP |
● |
● |
ARP proxy |
basic ARP-Proxy |
● |
● |
local ARP-Proxy |
● |
● |
IPv4 Unicast Routing |
IPv4 Static Routes |
IPv4 Static Routes |
● |
● |
uRPF |
uRPF check |
● |
● |
RIP |
RIPv1/v2 |
○ |
● |
OSPFv2 |
OSPFv2 |
○ |
● |
IS-IS |
IS-IS |
○ |
● |
BGP |
BGP |
● |
● |
ICMP |
ICMP redirect |
● |
● |
ICMP unreachables |
● |
● |
ECMP |
ECMP |
● |
● |
IPv4 Multicast Routing |
IGMP |
IGMPv1/v2/v3 |
● |
● |
IGMP-Proxy |
● |
● |
IGMP SSM Mapping |
● |
● |
PIM |
PIM-SM |
● |
● |
PIM-SSM |
● |
● |
PIM-DM |
● |
● |
IPv6 Forwarding |
IPv6 Basic Protocol |
ICMPv6 |
ICMPv6 |
● |
● |
NDP |
NDP |
● |
● |
PMTU |
PMTU |
● |
● |
IPv6 Unicast Routing |
IPv6 Static Routes |
IPv6 Static Routes |
● |
● |
RIPng |
RIPng |
● |
● |
BGP4+ |
BGP4+ |
● |
● |
OSPFv3 |
OSPFv3 |
● |
● |
IS-IS |
IS-IS |
● |
● |
IPv6 Multicast Routing |
MLD v1/v2 |
MLD v1/v2 |
● |
● |
MLD v1/v2 Snooping |
MLD v1/v2 Snooping |
● |
● |
Reliability |
BFD |
BFD |
BFD for OSPFv2 |
● |
● |
VRRP |
VRRP |
VRRP |
● |
● |
Track for VRRP |
● |
● |
Smart Link |
FlexLink |
FlexLink |
● |
● |
Monitorlink |
Monitorlink |
● |
● |
ethernet OAM |
EFM |
EFM (802.3ah) |
Auto detection |
● |
● |
Network fault detetion |
● |
● |
Network fault handle |
● |
● |
remote loopback |
● |
● |
CFM |
CFM (802.1ag) |
Hardware CCM detect |
● |
● |
MAC Ping |
● |
● |
MAC Trace |
● |
● |
Y.1731 |
Y.1731 |
Latency and jitter measure |
● |
● |
QoS features |
QoS |
Traffic classification |
Traffic classification based on COS/DSCP (simple classification) |
● |
● |
Traffic classification based on ACL ( complex classification) |
● |
● |
Traffic classification based on inner header of the tunnel packets |
● |
● |
Traffic behaviors |
Queue scheduling |
● |
● |
Remark the priority fields(COS/DSCP) of the packet based on ACL |
● |
● |
Flow redirection |
● |
● |
Flow mirror |
● |
● |
Traffic policing |
Traffic policing based on direction(in/out) of Port |
● |
● |
Traffic policing based on direction(in/out) of VLAN |
● |
● |
Traffic policing based on direction(in/out) of flow |
● |
● |
Traffic policing based on direction(in/out) of aggregated flow |
● |
● |
Traffic shaping |
Queue based traffic shaping |
● |
● |
Port based traffic shaping |
● |
● |
Congestion management |
SP(Strict Priority)scheduling |
● |
● |
WRR(Weighted Round Robin)scheduling |
● |
● |
SP + WRR mixed scheduling |
● |
● |
Traffic statistics |
Packet counts and bytes statistics based on traffic classification |
● |
● |
Packet counts and bytes statistics based on the color after traffic policing |
● |
● |
Forwarded and discarded packet counts and bytes statistics |
● |
● |
Security and management |
System Security |
SSH |
SSHv1/v2 |
● |
● |
RADIUS |
RADIUS |
● |
● |
TACACS+ |
TACACS+ |
● |
● |
AAA |
Authentication |
● |
● |
Accounting |
● |
● |
Dot1x |
Port based dot1x |
● |
● |
MAC based dot1x |
● |
● |
ACL |
MAC/IP ACL |
● |
● |
Basic Mode ACL |
● |
● |
Port/VLAN/L4-Port ACL |
● |
● |
Time Range |
● |
● |
ARP Inspection |
ARP Inspection |
● |
● |
IP Source Guard |
IP Source Guard |
● |
● |
Port Security |
Limitation on MAC address learning on interface |
● |
● |
VLAN Security |
Limitation on MAC address learning on VLAN |
● |
● |
Rate limit |
Rate limit |
● |
● |
CPU Traffic Limit |
CPU Traffic Limit |
● |
● |
Prevent DDOS attack |
Prevent DDOS attack (ICMP Flood/Smurf/Fraggle/LAND/SYN Flood) |
● |
● |
Login filter |
CLI/WEB/SNMP/Telnet/SSH filtering |
● |
● |
Network Management |
DHCP |
DHCP Server |
● |
● |
DHCP Relay |
● |
● |
DHCP Snooping |
● |
● |
DHCP Option60 |
● |
● |
DHCP Option82 |
● |
● |
RMON |
RMON |
● |
● |
sFlow |
RFC3176 sFlow |
● |
● |
SNTP |
SNTP(Simple Network Time Protocol) |
● |
● |
LLDP |
LLDP |
● |
● |
Configuration and maintenance |
Terminal Services |
Command Line Interface |
Configurations through CLI (Command Line Interface) |
● |
● |
Help information |
Help information in English |
● |
● |
Terminal service |
Vty Terminal service |
● |
● |
Console Terminal service |
● |
● |
Configuration Management |
Management interface |
Inband management interface and configuration |
● |
● |
Outband management interface and configuration |
● |
● |
User privilege management |
privileged user proirity and privileged commands |
● |
● |
SNMP |
Network management based on SNMPv1/v2c/v3 |
● |
● |
Public and private MIB |
● |
● |
Public and private Trap |
● |
● |
WEB |
Configuration and management based on WEB UI |
● |
● |
Restore factory default configuration |
Restore factory default configuration |
● |
● |
File System |
File system |
File system |
● |
● |
Upload and download |
Upload and download files through FTP or TFTP |
● |
● |
Upload and download files through Xmodem |
● |
● |
Debugging And Maintenance |
Debug |
per-module Debug features |
● |
● |
ICMP Debug |
● |
● |
Log & Alarm |
CPU usage display and alarm |
● |
● |
Memory usage display and alarm |
● |
● |
Device temperature、PSU、FAN、status display and alarm |
● |
● |
User operation logs |
● |
● |
Management of logs, alarms, and debugging information |
● |
● |
VCT |
VCT(Virtual Cable Test) |
● |
● |
system diagnostics |
Detailed Diagnostic-information collection |
● |
● |
Reboot |
Manual reboot |
● |
● |
Schedule Reboot |
● |
● |
Reboot Information logging |
● |
● |
Network diagnostics |
Ping |
● |
● |
IPv6 Ping |
● |
● |
Traceroute |
● |
● |
Mirror |
Port mirror |
● |
● |
Flow mirror |
● |
● |
Remote mirror |
● |
● |
Multi-destination mirror(m:n) |
● |
● |
CPU statistics |
To CPU/From CPU packets statistics |
● |
● |
Loopback |
port loopback |
● |
● |
hardware loopback(internal/external) |
● |
● |
System time |
Time configuration |
● |
● |
Timezone |
● |
● |
Version Upgrade |
System soft ware upgrade |
upgrade with the local image file |
● |
● |
upgrade with the remote TFTP server |
● |
● |
Uboot upgrade |
Online upgrade Uboot |
● |
● |
Performance & Spec Table |
Class |
Feature |
Sub Spec |
S2624-4X |
S2648-6X |
Ethernet Basic |
Jumbo frame |
Maximum Jumbo frame size |
12288 |
Switching Capacity |
Switching Capability |
128 Gbps |
216 Gbps |
Throughput |
95.232 Mpps |
160.704 Mpps |
Latency |
Min: 660ns |
MAC |
MAC address Capacity |
16K |
32K |
MAC Learning Rate (HW) |
Line Rate |
Line Rate |
Multicast MAC |
Multicast MAC address Capacity |
1023 |
4095 |
VLAN |
VLAN IDs |
4094 |
MAC-VLAN Capacity |
1K |
2K |
IP-subnet-vlan Capacity |
1K |
2K |
Protocol-VLAN Capacity |
8 |
VLAN Swap Capacity |
1K |
2K |
Link Aggregation
(Static&LACP) |
Maximum Member Num per group |
8 |
Maximum Group Num |
64 |
128 |
Load balance policy |
Dst-ip/Src-IP/Dst-MAC/Src-MAC |
Convergence time |
< 50ms |
Port-isolate |
Port-isolate Group Num |
4 |
Ethernet Ring protection |
STP |
Convergence time |
< 30s |
RSTP |
Convergence time |
< 1s |
MSTP |
Instance Num |
16 |
Convergence time |
< 1s |
ERPS(G.8032) |
Rings |
239 |
Switchover time |
< 50 ms |
Ethernet OAM |
CFM(802.1ag) |
Maximum Session Num |
48 |
Maximum domain Num |
8 |
CCM Interval Types |
4 |
Maximum Down MEP Num |
8191 |
Maximum Up MEP Num |
8191 |
IPv4 unicast |
ARP |
ARP Capacity |
6K |
12K |
IPv4 |
LPM |
512 |
12K |
IPv4 multicast |
IGMP Snooping |
Maximum Groups Num |
1K |
4K |
IPv6 unicast |
Host Route |
NDP Capacity |
3K |
12K |
IPv6 |
LPMv6 |
128 |
12K |
QACL |
Per-port Queue Num |
Queue Num |
8 |
Packet Buffer |
System Packet Buffer Capacity |
12M |
16M |
ACL |
ACL Capacity |
2K |
4K |
Security |
IP Source Guard |
IPv4 IP-Source-Guard Capacity |
1K |
IPv6 IP-Source-Guard Capacity |
1K |
802.1x base MAC |
Maximum Entries |
1K |
DHCP-Snooping |
Maximum bound entry |
1K |
Reliability |
VRRP |
Maximum Group Num |
255 |
Smart Link |
Flexlink Num |
128 |
MonitorLink Num |
5 |